Release Notes for WinMark Pro version 5.1.1.5942
This file contains the latest release notes for WinMark Pro, version 5.1.1, build 5942.
OPERATING SYSTEM:
WinMark Pro version 5 software (WinMark_Setup.EXE) is intended for use only with Microsoft® Windows® Vista™, XP, and 2000, operating systems. WinMark Pro version 5 is compatible with all SYNRAD FH Series Flyer Marking Heads.
WinMark Pro version 5.1.1.5942 software is NOT fully tested for compatibility with FH Series Index and Tracker Marking Heads. WinMark Pro v5 is NOT intended for use with marking heads using an ISA-bus Fiber Link Controller Card (FLCC).
WINMARK PRO REQUIREMENTS
16-MB RAM
30-MB of free hard drive space
0ne CD-ROM drive
Two open USB ports (one for USB Hardlock device, one for Flyer communications)
SYSTEM REQUIREMENTS:
Windows Vista:
800 MHz processor
512-MB RAM
20-GB hard drive with at least 15 GB of available space
CD-ROM drive
Support for Super VGA graphics
Windows XP:
Pentium-compatible CPU, 233 MHz or faster (300 MHz recommended)
64-MB RAM (128 MB recommended)
20-MB available hard disk space
CD-ROM drive
Super VGA or higher-resolution display adaptor (16-bit or 24-bit SVGA color monitor recommended)
One open PCI-bus slot
Windows 2000:
Pentium-compatible CPU, 133 MHz or faster
64-MB RAM
20-MB available hard drive space
CD-ROM drive
16-bit or 24-bit SVGA color monitor recommended
INSTALLATION:
We recommend that WinMark Pro version 5 software be installed before connecting and powering the FH Flyer Marking Head. Version 5 automatically loads the correct device drivers during installation. If WinMark Pro is not installed first, the Windows operating system will arbitrarily assign a USB driver that is NOT compatible with Flyer’s USB port protocols.
IMPORTANT INSTALLATION NOTE:
With Microsoft Windows Vista, XP, and 2000 operating systems, programs must be installed or uninstalled by an individual with Administrator privileges. Because of this behavior, WinMark Pro’s registry access permissions are initially set to Administrator by the WinMark installer when it sets the startup language. The installer does not support different access levels for registry keys so these must be changed by the program. It is therefore necessary to run WinMark Pro once as an Administrator before other, more restricted, users can run the program. On Vista operating systems, you may be required to log on as the Administrator in order to perform certain functions including Custom Test Mark downloads and file importation or when saving custom date code formats.
Version 5.1.1.5942
- ActiveX: SAGetCurrentFilePath returns the mark file that the standalone Flyer is currently using.
- Abort mark session is functional in standalone Flyer.
Version 5.1.1.5937
- ActiveX: SetCurrentMarkingHead correctly configures Flyer marking head.
- Stand-alone ActiveX: GetSAMarkStats reports mark information after EOM received.
Version 5.1.1.5929
- Added custom Shift codes to MKH (for Flyer standalone mode).
- Stand-alone ActiveX: GetFilestoreInfo fixed.
- Stand-alone ActiveX: GetMarkmode fixed.
- Language select issue fixed.
Version 5.1.1.5916
- Added IP address range enhancements to Flyer Ethernet Security: IP address validation, global IP address range password.
- Mouse and keyboard input disabled when Mark Dialog Box initiates a mark session.
- Added "Allow External Part Trigger" property to tracking parameters on the marking head property page.
Version 5.1.1.5899
- Added descriptive text to Flyer IP Address Range dialog box
- Fixed firmware version for FH heads where version '3' showed rather than '20'
Version 5.1.1.5884
- Added IP address ranges for Ethernet Security feature on the Flyer Head
- Fixed problem where second Instance of WMP goes into demo mode, but subsequent Instances do not. Instances 3, 4, etc connect to same head
- Changed 2D Barcode Quiet Zone property default to YES
- Fixed problem in demo mode where the head type, lens type, and device tab did not agree with selected head (since the demo selection list was reordered)
Version 5.1.1.5882
- Fixed error in the ActiveX method – AddImport
- Removed unused 'File Store' prop from Tools menu and 'Show Device Dialog' prop on Devices menu.
Version 5.1.1.5871
- Added ActiveX method to abort marking in standalone mode
- Added additional error handling to Winmark/Flyer EOM processing
Version 5.1.1.5865
- Fixed bug with \xxx text entry - shows control chars during edit
- Set Text Curve Detail to 500 AND added to ObjectDefaults tab
- Barcode Number prop jumps up on Format tab
Version 5.1.1.5855
- Text caption editor opens when text or barcode type object is double-clicked
- Added Flyer/FHIN/FHTR simulation to ActiveX
- Changed simulation list : Flyer, FH, Smart, then HurryScan
- Added standalone support to v5 ActiveX.
Version 5.1.1.5815
12/11/2007
- Fixed some issues with multiple marking head and multiple WinMark instance functionality.
- Fixed issue with Close button being enabled on the “Launcher” window.
- Fixed WinMark import graphic file resolution issue.
- Fixed Mark Field Size issue with FH Marking heads.
- Fixed issues with the Ethernet Address Box and Retry options in the Device Simulation Dialog Box.
- Fixed issue concerning power commands to FH heads.
- Fixed persistence issue with Ethernet parameters.
- Added “control characters in text dialog box” feature.
Version 5.1.1.5759
10/30/2007
- Identified potential Flyer device driver runtime errors using Microsoft’s driver test tool – Driver Verifier. Changed code accordingly to remove potential problems.
Version 5.1.1.5723
9/21/2007
- Fixed memory pool violation error in the Flyer device driver. Problem caused intermittent system crashes – “Blue Screen of Death”.
- First V5 release to support multiple marking heads and multiple WinMark instances.
Version 5.1.0.5705
8/21/2007
- Added Clearing Mark functionality for Flyer.
- Added Use Control File property.
Version 5.1.0.5676
7/31/2007
- Developed to fully support Flyer v2.0 firmware upgrade.
- Added a User Interface to change the Time/Date and the DST settings.
- Added a toolbar to access the file store and do many of the file operations necessary to operate the Flyer head in Standalone mode.
- Added copy/paste drag/drop functionality to toolbar to facilitate the ease of use of moving files to/from the Filestore.
- Changed the Mark Dialog to display differently in standalone mode. It shows different statistics and there is no preview.
- Changed WinMark Launcher so that it has capability of communicating with Flyer in Standalone mode and opening files in the Filestore.
- Added all of the functionality necessary for WinMark to tell Flyer to open a mark file on a network share and whether the share is available.
- Added all of the properties necessary for Standalone marking, and the ability to switch between Standalone and tethered (USB/Ethernet) marking.
- Added the standalone toolbar that allows the four most common operations at your fingertips.
- Changed the tool tip for the Mark button so that in Standalone mode it shows the full path of the current mark file loaded.
- Many small fixes for both improving Standalone and tethered (USB/Ethernet) marking.
Version 5.0.0.5577
4/9/2007
- Fixed a bug where opening a file with Drawing transformations would be lost. The Drawing transformations are now set to what is saved in the file.
- Fixed languages so that users can switch between them.
- Minor fixes to prevent lock-ups, and allow a user to try and update a head more than once if it fails. Some of these changes will take advantage of fixes in firmware 1.03
- Fixed some Vista compatibility issues. The Test Mark should now work in Vista.
- Fixed a clunk on bitmaps that would occur in certain cases at the end of the entity.
- Removed Disable Marking property from the FH settings as the property is now obsolete.
Version 5.0.0.5558
3/27/2007
- Changed default marking parameters to Flyer defaults:
Pline Start Delay = 0 usec
Pline End Delay = 200 usec
Interseg Delay = 75 usec
Off Vector Delay = 250 usec
Off Vector Velocity = 200”/sec
- Fixed memory leaks in Flyer USB driver. These should fix the slow (~ 5 day) memory leak.
- Moved "last drawing" for Launcher from marking head registry keys to the Synrad startup registry key. Marking head keys are removed when WinMark shuts down.
- Added "serial number" identification for ALL marking heads. Flyer uses device serial number, FH uses PCI device ID, Smart FH can use its device serial number, ScanLab uses device serial number. The use of device serial number identification uniquely identifies a marking head. It removes any possible conflicts with marking heads that have the same name.
- Fixed "connect to Ethernet Flyer" from WinMark Device menu. Added the "connect to Ethernet Flyer" menu item to Launcher’s Device menu.
- Fixed WinMark Flyer connect issues:
In simulation mode - connect currently selected USB Flyer. User must select head.
Disconnect currently selected USB Flyer head. Re-connect Flyer head. Head is automatically selected.
Disconnect currently selected USB Flyer head. Re-connect another USB Flyer head. New Flyer head is automatically selected.
USB Flyer automatically re-connects when head is powered down and subsequently powered up.
Select FH marking head. Connect USB Flyer head. FH head still is currently selected head.
- Improved USB connect/disconnect notification to WinMark, Launcher, DigiScope and SynMhAtx.
- Added a Head Info button to the About dialog box from the Help menu. Click on the button to show General Setting property pages, the marking head property page becomes the active page.
- Removed text (Ver. & ID) from versions on FH marking head property page.
- Fixed FH version format (e.g. v20) on FH marking head property page. WinMark can also now mark to Firmware version 10.
- WinMark selects the last marking head used on startup.
- Fixed File Open and Flyer disconnect (or select new marking head) problem.
- FH now can now change to other lenses besides the 200mm lens.
- Changed the program to use a registry key with the version "V5" under the “Synrad WinMark” key so that it does not conflict with the V4 registry.
- Changed the Curve Detail on a text object to default to 500.
- The Ethernet Flyer will now gray out the button when a disconnected is detected.
- The FH driver now calculates the Polyline Start Delay correctly. This was causing small letters to not be marked.
- ActiveX now can get USB disconnect/connect events. This has been shown in WMAddLine, which is also changed.
- Added the 2d barcode upgrades, PrintGrowth and rounded rectangle.
- Added the MicroPDF barcode format.
- Changes to install file to include support for Windows Vista and firmware updates for Flyer.
- Fixed multiple Tracking and Wait Digital / Match Digital issues on Flyer. These changes also require firmware 1.02 or better running on Flyer.
- The install was not correctly cleaning the registry when the user selected to perform a clean installation. This has now been corrected and the install has also been updated to reflect the registry changes necessary to keep V5 separate from V4. Also the user is shown that the install for V5 is new and is using a blank key by the “Perform Clean Installation” and “Keep Current Program Settings” choices being grayed out on the “Save Current Registry Settings” dialog. This is a visual cue that V5 is installing under the new V5 key and will be a clean install as is.
NOTE: Performing a clean install with V5 will leave the Settings for V4 as is.
Important Note: Performing a clean install with V4 will wipe the V5 and V4 settings.
- The installation program now does a better job of forcing windows to install the newer drivers for the FH and USB. This was a problem under XP and Vista when an older version had already installed the drivers and the newer version was not replacing them.
Version 5.0.0.5497